1.
Rev. cuba. ortop. traumatol ; 35(2): e413, 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1341474

ABSTRACT

Introducción: La cirugía de la artroplastia y el recambio de una prótesis de cadera es una cirugía compleja y costosa. La estrategia quirúrgica y componentes protésicos son completamente diferentes en función de las deformidades óseas existentes y características anatómicas personales de cada paciente, por tanto, la planificación de suministros de los diferentes componentes es básica para cubrir las demandas de la población necesitada y la adecuada eficiencia económica para evitar gastos innecesarios por sobreestimación o infraestimación de las demandas. Objetivos: Determinar las necesidades por medidas de los diferentes tipos de componentes protésicos utilizados en la artroplastia total de cadera en las provincias centrales y de este modo optimizar las inversiones, con las ventajas económicas que supone. Métodos: Estudio longitudinal descriptivo retrospectivo de los casos operados de artroplastia total de cadera en el Hospital Arnaldo Milián Castro de Villa Clara, desde diciembre de 1998 hasta la fecha. Se analizan las variables edad, sexo, procedencia y componentes protésicos. Se recoge la información en la base de datos creada en SPSS, donde se realizan los análisis estadísticos. Resultados: La edad media fue 62,36 años. El grupo de 61 - 80 años fue el de mayor incidencia con 215 pacientes. Predominó el sexo masculino 51,8 por ciento. La mayor incidencia, correspondió a Villa Clara con 692 pacientes. Los componentes cementados 46 - 50 fueron los más usados y en los no cementados los más usados fueron 48-56. Vástagos Tipo Müller 7.5 - 12.5. RALCA Cementadas T0-T4, no cementados T1-T3. En las SLA, 11.5 y 13. Los cuellos estándar fueron los de mayor incidencia con 390 pacientes. Conclusiones: Con las incidencias de las diferentes medidas utilizadas por cada uno de los componentes expresados, se puede determinar con bastante exactitud la demanda de cada medida por cada 100 casos pendientes de operación. Esto permite satisfacer las demandas de las medidas más usadas y hacer una distribución apropiada a la hora del suministro, lo que redundaría en un beneficio económico vital en las actuales condiciones del país(AU)


Introduction: The arthroplasty surgery and the replacement of a hip replacement is a complex and expensive surgery. The surgical strategy and prosthetic components are completely different depending on the existing bone deformities and personal anatomical characteristics of each patient, therefore, the planning of supplies of the different components is essential to meet the demands of the needy population and adequate economic efficiency to avoid unnecessary expenses due to overestimation or underestimation of claims. Objective: To determine the needs by measurements of the different types of prosthetic components used in total hip arthroplasty in the central provinces and thus optimize investments, with the economic advantages that it entails. Methods: A retrospective descriptive longitudinal study was carried out of the total hip arthroplasty operated cases at Arnaldo Milián Castro Hospital in Villa Clara, from December 1998 to date. Age, sex, origin and prosthetic components are the variables examined. The information is collected in the database created in SPSS, statistical analyzes was performed. Results: The mean age was 62.36 years. The group of 61-80 years was the one with the highest incidence (215 patients). Male sex predominated (51.8 percent). The highest incidence corresponded to Villa Clara (692 patients). The cemented components 46-50 were the most used and in the uncemented components the most used were 48-56. Müller Stems 7.5 - 12.5. RALCA Cemented T0-T4, uncemented T1-T3. In the SLA the most used were 11.5 and 13 respectively. Standard necks were those with the highest incidence (390 patients). Conclusions: The demand for each measure can be determined quite accurately for every 100 cases pending operation with the incidents of the different measures used by each of the components expressed, allowing to meet the demands of the most used measures and appropriate distribution at supplying, which would result in vital economic benefit in the current conditions of the country(AU)


Subject(s)
Humans , Adolescent , Adult , Middle Aged , Aged , Aged, 80 and over , Incidence , Arthroplasty, Replacement, Hip/methods , Procedures and Techniques Utilization , Joint Prosthesis , Retrospective Studies , Longitudinal Studies
2.
Article in Portuguese | LILACS, BBO | ID: lil-561097

ABSTRACT

Este trabalho apresenta características e resultados de ensaios realizados em componentes protéticos utilizados em implantes com conexão cônica interna. Nele estão descritas as características principais dos componentes protéticos e o sistema de fresagem para inserção do implante de acordo com a classificação óssea.


This work shows characteristics and tests results of implant prosthetics components used with internal taper connection. There are described the main characteristics of the prosthetics components and milling system for insertion of the implant according to the bone classification.


Subject(s)
Dental Implantation, Endosseous , Torque , Dental Cements , Dental Prosthesis, Implant-Supported
3.
The Journal of Korean Academy of Prosthodontics ; : 374-385, 2002.
Article in Korean | WPRIM | ID: wpr-49099

ABSTRACT

A total of 605 implant fixture prosthesis delivered by 3 clinics and 2 laboratories were examined in this study. The object of this study was to determine the proper length of screw head. The depth of access hole were measured and compared to the type of fixture, abutment, gold screw and prosthesis. The results were as follows: 1. The average number of fixtures per patient were 2.97. 2. The number of fixture installed in the lower posterior area are 327(55.56 %), the upper posterior area 171(28.25%). 3. The depth of access hole is 4.23 mm in shallow area, and 5.46 mm in deep area and the differences were 1.23 mm. 4. The average depth of the aceess hole of the UCLA abutment were 5.02 mm. 5. The number of 4-5 mm access hole depth were 60(22.39%)in abutment screw level and the number of 4-5 mm depth in fixture level were 101(29.19%). 6. In the shape of screw head, hexed type were 576(95.21%), slotted type were 29(4.79%).


Subject(s)
Humans , Head , Prostheses and Implants